230.3 Charges for additional facilities

 

(a) If, in order to provide service to an applicant, the gas corporation must install mains and appurtenant facilities in addition to those required to be provided without charge under section 230.2 of this Part, the corporation shall impose a surcharge subject to the following provisions.

(1) The surcharge relating to mains and appurtenant facilities including return, depreciation, taxes and maintenance shall not exceed 20 percent per year of the actual reasonable cost of such facilities that exceeds the portion which the corporation is required to install without charge to an applicant, if the corporation lays a main of four inches or less in nominal diameter (in the case of low pressure distribution) or of two inches or less in nominal diameter (in the case of high pressure distribution). If the corporation lays a main greater than four inches in nominal diameter (in the case of low pressure distribution) or greater than two inches in nominal diameter (in the case of high pressure distribution), the surcharge shall not exceed 20 percent per year of the estimated reasonable cost of a four-inch main (in the case of low pressure distribution), unless the estimated consumption of the proposed customer(s) requires the installation of a larger-sized main, in which event the surcharge shall not exceed 20 percent per year of the actual reasonable cost of such main. The surcharge shall commence when gas service is first available to an applicant and shall be paid ratably for each billing period.

(2) The surcharge shall be reduced by 50 percent of adjusted gas revenues, but the credit shall not exceed the amount of the surcharge as determined above.

(3) Whenever more than one customer is connected to a main extension, the surcharge shall be so adjusted that the corporation shall not receive in any one calendar year a greater percentage from all customers served from the main extension than that applicable to such extension. The surcharge shall also be reasonably allocated among the customers being served from the main extension, taking into account the portion of mains and appurtenant facilities which the corporation is required to provide without charge to each customer served from such facilities.

(4) Each surcharge shall cease:

(i) whenever the length of a main extension required to be provided without charge to all customers served from such extension shall equal or exceed the total length of such extension;

(ii) whenever the total adjusted gas revenue from all customers served from a main extension shall equal or exceed 40 percent of the cost of such extension in excess of that required to be provided without charge, in each of any two consecutive calendar years; or

(iii) after a period of 10 years following its commencement.

(5) Should the adjusted gas revenue from all customers served from a main extension exceed the carrying cost of the entire extension, any surcharges (or contributions) paid by such customers during the preceding five years shall be refunded to such customers.

(6) No surcharge shall be imposed if the total adjusted gas revenue from all customers served from a main extension is estimated to exceed 40 percent of the actual reasonable cost of such extension in each of any two consecutive calendar years.

(b) If, in order to provide service to an applicant, the gas corporation must install service lines, service connections and appurtenant facilities in addition to those required to be provided without charge under section 230.2 of this Part, the corporation may impose a charge for material and installation costs as set forth in its tariff approved by the commission.