255.711 - Transmission lines: General requirements for repair procedures

 

(a) Temporary repairs. Each operator must take immediate temporary measures to protect the public whenever:

(1) a leak, imperfection, or damage that impairs its serviceability is found in a segment of steel transmission line, or distribution main operating at 125 psig (862 kPa) or more in a Class 3 or 4 location; and

(2) it is not feasible to make a permanent repair at the time of discovery.

(b) Permanent repairs. An operator must make permanent repairs on its pipeline system according to the following:

(1) non integrity management repairs. The operator must make permanent repairs as soon as feasible;

(2) integrity management repairs. When an operator discovers a condition on a pipeline covered under Subpart O-Gas Transmission Pipeline Integrity Management, the operator must remediate the condition as prescribed by section 255.933(d) of this Part.

(c) Welded patch. Except a provided in section 255.717(b)(3) of this Part, no operator may use a welded patch as a means of repair.