Rules For Reinforcement Of Welded Branch Connections

 

image\east0007_wmf.gif

 

"Area of Reinforcement" enclosed by _________ - _______ Lines

 

Reinforcement Area Required AR = (d) (t)

Area Available as Reinforcement = A1 + A2 + A3

 

A1

=

(H - t) (d)

A2

=

2(B - tb) L

A3

=

Summation of Area of All Added Reinforcement, Including Weld Areas which lie within the "Area of Reinforcement"

 

 

A1 + A2 + A3 must be equal to or greater than AR

 

Where:

 

H

=

Nominal Wall Thickness of Header

B

=

Nominal Wall Thickness of Branch

tb

=

Required Nominal Wall Thickness of the Branch

(Under the appropriate section of the Guide)

t

=

Required Nominal Wall Thickness of the Header

(Under the appropriate section of the Guide)

d

=

The Length of the Finished Opening in the Header Wall

(Measured parallel to the Area of the Header)

M

=

Actual (by measurement) or Nominal

Thickness of Added Reinforcement